CLJ-E301 Laser Particle Counter is designed on the base of light scattering principle of particles, in compliance with standards of FDA-209 (USA) and JGJ171-90 (China), with features of multifunction, standardized data and high accuracy. This product use He-Ne laser as light source, which has features of single wave, energy concentration to make instrument has higher sensitivity.
Features and Specification
1. light source: laser
2. sampling volume: 2.83L/min(0.1cfm/min)
3. measurement scope: 100~1000000 class
4. sampling time: 1~10 (min)
5. zero count: ≤15 (min)
6. max. power consumption: 25W
7. number of sampling place: 2~7
8. sampling times for each sampling place: 2~9
9. working time:8 hours
10. weight: 3kg
11. overall dim.(mm): 200×280×110
12. power supply: AC(220V, 50HZ)/DC(4 hours working time)
13. max. allowed particle concentration: ≯100000 pcs/2.83L
14. particle size channels: 0.3 0.5 1.0 3.0 5.0 10.0 (μm)
15. calculation: can convert the value of 2.83L to the value of 1m3
16. working condition: temperature:10~35℃; relative humidity:20~75%RH
17. temperature & humidity measurement scope and accuracy: (optional)
(1) temperature: 0~50℃±1℃
(2) humidity: 0~100%RH±5%
18. UCL report: in compliance with FS-209 (USA), GMP (China)
19. Calibration: can be calibrated by National Institute of Standards & Technology (NIST), Shanghai Institute of Measurement and Testing Technology (SIMT), third party National Measurement Institutes or by self.
20. Up to six channels or self-select channels of simultaneous data display
21. Remark: build-in printer, self-, isokinetic probe, sampling bracket, 1000 group data storage. (temp & RH probe as an optional accessory)
Features and Specification
1. light source: laser
2. sampling volume: 2.83L/min(0.1cfm/min)
3. measurement scope: 100~1000000 class
4. sampling time: 1~10 (min)
5. zero count: ≤15 (min)
6. max. power consumption: 25W
7. number of sampling place: 2~7
8. sampling times for each sampling place: 2~9
9. working time:8 hours
10. weight: 3kg
11. overall dim.(mm): 200×280×110
12. power supply: AC(220V, 50HZ)/DC(4 hours working time)
13. max. allowed particle concentration: ≯100000 pcs/2.83L
14. particle size channels: 0.3 0.5 1.0 3.0 5.0 10.0 (μm)
15. calculation: can convert the value of 2.83L to the value of 1m3
16. working condition: temperature:10~35℃; relative humidity:20~75%RH
17. temperature & humidity measurement scope and accuracy: (optional)
(1) temperature: 0~50℃±1℃
(2) humidity: 0~100%RH±5%
18. UCL report: in compliance with FS-209 (USA), GMP (China)
19. Calibration: can be calibrated by National Institute of Standards & Technology (NIST), Shanghai Institute of Measurement and Testing Technology (SIMT), third party National Measurement Institutes or by self.
20. Up to six channels or self-select channels of simultaneous data display
21. Remark: build-in printer, self-, isokinetic probe, sampling bracket, 1000 group data storage. (temp & RH probe as an optional accessory)